beautypg.com

Delta Electronics AC Motor Drives VFD-XXXE User Manual

Page 20

background image

English- 20

Pr.

Explanation

Settings

Factory

Setting

NOTE

Bit8: MI9 Status
Bit9: MI10 Status
Bit10: MI11 Status
Bit11: MI12 Status

04.27

Internal/External
Multi-function Input
Terminals Selection

0~4095 0

a

04.28

Internal Terminal
Status

0~4095 0

Group 5 Multi-Step Speeds Parameters

a

05.00

1st Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.01

2nd Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.02

3rd Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.03 4th

Step

Speed

Frequency

0.00 to 600.0 Hz

0.00

a

05.04 5th

Step

Speed

Frequency

0.00 to 600.0 Hz

0.00

a

05.05 6th

Step

Speed

Frequency

0.00 to 600.0 Hz

0.00

a

05.06 7th

Step

Speed

Frequency

0.00 to 600.0 Hz

0.00

a

05.07 8th

Step

Speed

Frequency

0.00 to 600.0 Hz

0.00

a

05.08 9th

Step

Speed

Frequency

0.00 to 600.0 Hz

0.00

a

05.09

10th Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.10

11th Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.11

12th Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.12

13th Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.13

14th Step Speed
Frequency

0.00 to 600.0 Hz

0.00

a

05.14

15th Step Speed
Frequency

0.00 to 600.0 Hz

0.00

Group 6 Protection Parameters

115/230V series: 330.0V to 410.0V

390.0V

460V series: 660.0V to 820.0V

780.0V

06.00

Over-Voltage Stall
Prevention

0.0: Disable over-voltage stall prevention

06.01

Over-Current Stall
Prevention during
Accel

0:Disable
20 to 250%

170

06.02

Over-Current Stall
Prevention during
Operation

0:Disable
20 to 250%

170