EXFO FTB-635 Wideband Copper and DSL Test Module User Manual
Page 203
![background image](/manuals/736420/203/background.png)
TDR Test
Copper and xDSL Tests
195
Manual TDR
Note: In order to configure Trace 1 as Differential, at least two traces must be
enabled.
Note: If Trace 1 is configured as Differential and no trace is held or loaded, then
Trace 1 will display the normal TDR trace.
Differential Color option opens a color panel which allows you to
differentiate between Trace 2, Trace 3 and Trace 1. If Type is
Normal for Trace 1, its color is black and the color option is
disabled.
Trace 2/3: When enabled the following parameters can be set:
Type allows you to configure each trace as the following:
Hold - using this trace to display static snapshots of the live normal
TDR (regardless of whether Trace 1 is configured as Normal or
Differential) or
Load - displaying traces loaded from a file.
Offset: Each trace has a configurable offset, ranging from -1.00 to
1.00. The offset for Trace 1 (Live) is fixed at 0.00. If three traces are
enabled, all with Offset: 0.0, then all three traces will overlap.
Trace Color option opens a color panel which allows you to
differentiate between all 3 traces.
Prompt When Loading allows you to change TDR parameters to that
of the loaded file, either a Single Trace or Trace Group (multiple
traces) when enabled.
Clear Held/Loaded Traces button clears the parameters set for all
held or loaded traces.