beautypg.com

Raid volume data verification and repair – Eurocom Panther 3.0 User Manual

Page 146

background image

Modules

7 - 10 Intel Rapid Storage Technology

7

RAID Volume Data Verification and Repair

The RAID volume data verification process identifies any inconsistencies or bad
data on a RAID 0 or RAID 1 volume. The table outlines what occurs for each RAID
level:

Replacing and Reverting Recovery and Master Volumes

If a master or recovery drive fails you will need to add a new identical drive and re-
build the recovery volume to the drive. You can also revert the master drive to the
state of the previous volume update. For details on how to do this see

“Intel® Rapid

Storage Technology Help” on page 7 - 11

.

See over for details on how to verify and repair RAID volume data.

RAID

Level

Verify

Verify & Repair

RAID 0

Bad blocks are identified.

N/A

RAID 1

Bad blocks are identified.

Data on the mirrored drive is compared to
data on the source drive.

Bad blocks are reassigned.

If the data on the mirrored drive does not
match the data on the source drive, the
data on the mirrored drive is overwritten by
the data on the source.

RAID 5

Bad blocks are identified.

Parity is recalculated and compared to the
stored parity for that stripe.

Bad blocks are reassigned.

If the newly calculated parity does not
match the stored parity, the stored parity is
overwritten with the newly calculated parity.

Table 7 - 2

RAID Verification &

Repair Status