RT115 Tier 3- SERVICE

50 HOUR SERVICE

178

RT115 Tier 3 - SERVICE

50 HOUR SERVICE

Plow

Change Plow Vibrator Oil

Change plow vibrator oil after first 50 hours of operation.

Drain oil at drain plug (2). Replace plug and move plow vibrator to
horizontal position. Fill with MPL at fill (1) until oil is halfway up
sight glass (2). Refill capacity is 4 qt (3.8 L).

Saw

Lube Saw Lift Arm Pivot

Wipe zerks clean and lube saw lift arm pivots every 50 hours with
EPG.

IMPORTANT: Do not drain oil from plow vibrator when hot. Let
plow vibrator cool before removing drain plug.

Plow

Change Plow Vibrator Oil

Change plow vibrator oil after first 50 hours of operation.

Drain oil at drain plug (2). Replace plug and move plow vibrator to
horizontal position. Fill with MPL at fill (1) until oil is halfway up
sight glass (2). Refill capacity is 4 qt (3.8 L).

Saw

Lube Saw Lift Arm Pivot

Wipe zerks clean and lube saw lift arm pivots every 50 hours with
EPG.

IMPORTANT: Do not drain oil from plow vibrator when hot. Let
plow vibrator cool before removing drain plug.