Service - 96

FX60/FXT60 Tier 4 Operator’s Manual

10 Hour

CMW

®

Check Hydraulic Fluid Level

With frame level, check oil at indicator every 10
hours. Add THF at fill as necessary. Clean dust
from cap by blowing with low-pressure air.

Check Hydraulic Hoses

Check hoses every 10 hours for wear or damage.
Replace as needed.

IMPORTANT: Use a ladder or other means to
access hydraulic fluid fill.

Pressurized fluid or air could pierce skin and cause severe

injury. Refer to operator’s manual for proper use.

270-6035

To help avoid injury:

Before disconnecting a hydraulic line, turn engine off and operate all controls to relieve pressure.
Lower, block, or support any raised component with a hoist. Cover connection with heavy cloth and
loosen connector nut slightly to relieve residual pressure. Catch all fluid in a container.

Before using system, check that all connections are tight and all lines are undamaged.

Use a piece of cardboard or wood, rather than hands, to search for leaks.

Wear protective clothing, including gloves and eye protection.

If you are injured, seek immediate medical attention from a doctor familiar with this type of injury.