FX60/FXT60 Tier 4 Operator’s Manual
Service - 121
As Needed
CMW
®
Clean Secondary Shutoff Valve (1200
Tank)
Clean secondary shutoff valve as needed.
Replace secondary shutoff valve as needed.
To clean:
1.
Loosen wingnuts and open water trap door.
2.
Remove filter canister lid and remove filter
element.
3.
Drain water from element housing.
4.
Spray valve housing and rubber seat inside
water trap housing with high-pressure water.
5.
Disconnect water pressure hose and store
properly.
6.
Replace water filter canister lid and close water trap door.
7.
Tighten wingnuts.
To remove:
1.
Open hinged water trap door.
2.
Remove three fasteners inside water trap to remove ball housing.
3.
Clean ball and housing with high pressure water.
4.
Replace ball and housing.
5.
Close water trap door and tighten wingnuts.
2
1
j35om067h.eps
j35om067h.eps