Debris tank – Ditch Witch FXT60 User Manual
Page 121
Service - 120
FX60/FXT60 Tier 4 Operator’s Manual
As Needed
CMW
®
Debris Tank
Clean Primary Shutoff Valve
Clean primary shutoff valve as needed. Replace
primary shutoff valve as needed.
To clean:
1.
Open tank door. See “Open/Close Tank Door”
on page 78.
2.
Spray valve housing inside vacuum tank with
high-pressure water.
3.
Store water pressure hose.
4.
Close tank door. See “Open/Close Tank Door”
on page 78.
To remove:
1.
Loosen three wingnuts (1) and pull out valve housing (2).
2.
Remove ball (3).
3.
Clean ball and housing with high-pressure water.
4.
Replace ball and housing.
5.
Tighten wingnuts.
22
33
11
j35om027h.eps
j35om027h.eps
This manual is related to the following products: