Start unit, Standard procedure, Cold start procedure – Ditch Witch FXT60 User Manual
Page 70: E 69)
FX60/FXT60 Tier 4 Operator’s Manual
Vacuum and Pothole - 69
Start Unit
CMW
®
Start Unit
Standard Procedure
1.
Open tank inlet valve.
2.
If equipped with reverse flow, ensure vacuum is in “vacuum” mode before starting.
3.
Insert key.
4.
Turn key clockwise. See page 34 for more information.
5.
Run engine at low throttle for 5 minutes.
Cold Start Procedure
1.
Open tank inlet valve.
2.
If equipped with reverse flow, ensure vacuum is in “vacuum” mode before starting.
3.
Insert key.
4.
Wait for glow plug indicator to go out.
5.
Turn key clockwise. See page 34 for more information.
6.
Run engine at low throttle for 5 minutes.
EMERGENCY SHUTDOWN: Turn ignition switch to STOP.
IMPORTANT: If power pack is not connected to external tank control valves
(for 1200 gallon), connect a -08 hose with a minimum working pressure rating
of 3000 psi (207 bar) from return/tank (1) to pressure (2) connections on
power pack.
NOTICE: Avoid idling engine with inlet valve closed.
Fire or explosion possible. Do not use starter fluid.
273-459
(2P), 274-206 (2P), 700-206 (2P)
NOTICE: Avoid idling engine with inlet valve closed.