Service - 94
FX60/FXT60 Tier 4 Operator’s Manual
10 Hour
CMW
®
Vacuum System
Check Engine Oil Level
Check engine oil at dipstick (1) before operation
and every 10 hours thereafter. Check with unit on
level surface and at least 15 minutes after
stopping engine. Add DEO at fill (2) as necessary
to keep oil level at highest line on dipstick.
Drain Fuel/Water Separator
Drain water out of filter every 10 hours. To drain,
place loose end of drain hose into approved
container. Turn valve on bottom of filter
counterclockwise 4 turns until water flows out of
drain hose. When fuel comes out, turn valve
clockwise to close.
Inspect Belts
Check fan (2), blower (1), and water pump (3)
belts every 10 hours for damage or wear.