FX60/FXT60 Tier 4 Operator’s Manual
2000 Hour
CMW
®
Change Hydraulic Fluid
Drain hydraulic fluid (2) and add (1) THF every
1000 hours. Change fluid every 500 hours if
jobsite temperature exceeds 100°F (38°C) more
than 50% of the time.
2000 Hour
Vacuum System
Change Coolant
Drain cooling system at drain (1) every two years
or 2000 hours. Add approved coolant at
expansion tank (2) to fill line.
To fill:
1.
Slowly add coolant at expansion tank to fill line.
2.
Start and operate engine for several minutes after it reaches normal operating temperature of 195°F
(90°C).
3.
Stop engine and allow to cool.
4.
Repeat steps until coolant level is correct.
Location
Task
Notes
Vacuum
System
Change coolant
DEAC
NOTICE:
•
The use of non-approved coolant may lead
to engine damage or premature engine
failure and will void engine warranty.
•
See “Approved Coolant” on page 90 for list
of approved coolants.