Vacuum boom, 250 hour, Vacuum system – Ditch Witch FXT60 User Manual
Page 112
FX60/FXT60 Tier 4 Operator’s Manual
Service - 111
250 Hour
CMW
®
Vacuum Boom
Check Structure
Check boom deflector every 100 hours. Replace as needed.
250 Hour
Vacuum System
Change Engine Oil and Filter
Change oil and filter after 250 hours and every
250 hours if using oil meeting API CJ-4 or ACEA
E6/E9. See page 88 for more information about
DEO specifications.
1.
Drain crankcase through drain valve (1) while
oil is warm.
2.
Replace filter (2) each time oil is changed.
3.
Add 8.5 qt (8 L) of DEO at fill neck (4).
4.
Verify correct oil level at dipstick (3).
Location
Task
Notes
Vacuum
System
change engine oil and filter
DEO, initial and if using API
CJ-4 or ACEA E6/E9 oil
Inspect air intake system