Ditch Witch FXT60 User Manual
Page 119
Service - 118
FX60/FXT60 Tier 4 Operator’s Manual
As Needed
CMW
®
Change Blower Relief Air Filter
Check air filter whenever vacuum gauge goes
over 16” (406 mm) of mercury. Change as
needed.
1.
Remove clamp.
2.
Remove filter and discard.
3.
Install new filter.
4.
Replace clamp.
Empty Cyclonic Separator Canister
Empty cyclonic separator canister as needed.
Open door and dump tank. Clean out cyclone
through upper access door as needed.
Replace Water Pump Belt
Replace water pump belt (3) every 2000 hours.
Replace Blower Belt
Replace blower belt (2) every 2000 hours.
Replace Fan Belt
Replace fan belt (1) every 2000 hours.
NOTICE: Operating system above 16” (406
mm) of mercury may result in blower damage.
IMPORTANT: Depressurize tank before
emptying cyclonic canister, cleaning filter,
clearing hoses or opening any doors.
11
22
j35om069h.eps
j35om069h.eps