beautypg.com

Emergency procedures, Electric strike description – Ditch Witch FXT60 User Manual

Page 16

background image

FX60/FXT60 Tier 4 Operator’s Manual

Safety - 15

Emergency Procedures

CMW

®

Emergency Procedures

Before operating any equipment, review emergency procedures and check that all safety precautions have
been taken.

Electric Strike Description

When working near electric cables, remember the following:

Electricity follows all paths to ground, not just path of least resistance.

Pipes, hoses, and cables will conduct electricity back to all equipment.

Low voltage current can injure or kill. Many work-related electrocutions result from contact with less
than 440 volts.

Most electric strikes are not noticeable, but indications of a strike include:

power outage

smoke

explosion

popping noises

arcing electricity

If any of these occur, assume an electric strike has occurred.

Jobsite hazards could cause death or serious injury. Use

correct equipment and work methods. Use and maintain proper safety
equipment.

274-050

EMERGENCY SHUTDOWN - Turn ignition switch to stop position or push remote engine stop button (if
equipped).

Electric shock. Contacting electric lines will cause death

or serious injury. Know location of lines and stay away.