Open/Close Tank Door
CMW
®
Open/Close Tank Door
800 Tank:
Open
1.
If tank is tilted, lower tank fully before opening door.
2.
Open tank inlet valve.
3.
Set hydraulic function switch to door position.
4.
Press OPEN on tank controller.
Close
1.
Press CLOSE on tank controller until the linkage on both sides of the tank is fully collapsed.
2.
Close tank inlet valve.
Crushing weight. Place cylinder lock on extended cylinder
and secure.
273-231
To help avoid injury: Do not raise tank with door held closed only by vacuum. Door may suddenly
open and possibly injure someone.
NOTICE: Do not drive with tank or door raised.
IMPORTANT: Depressurize tank before emptying cyclonic canister, cleaning filter, clearing hoses or
opening any doors.