Vacuum system – Ditch Witch FXT60 User Manual
Page 117
Service - 116
FX60/FXT60 Tier 4 Operator’s Manual
As Needed
CMW
®
Vacuum System
Change Air Filter
Change air filter element when red band on filter
minder (1) is visible. Push button to reset
indicator.
To replace air filter:
1.
Disengage latches (2) and remove cover (3).
2.
Remove the primary (4) and secondary (5)
filters from the canister (6).
3.
Wipe out the canister (6) and cover (3) with a
damp cloth.
4.
Install the new secondary and primary filters
by hand with a slight turn and firm push to
seat the filters in the canister.
5.
Install the cover and engage latches.
6.
Reset filter minder indicator (1) by pressing the yellow button.
Change Water Pump Filter
1.
Open filter housing.
2.
Remove element and rinse housing
thoroughly with clean water.
3.
Install new element and close filter housing.
NOTICE: If the cover contacts the filter before the cover is fully in place, remove cover and push filter
element further into housing and try again. The cover should go on without extra force.
1
2
3
4
5
6
j35om062h.eps
j35om062h.eps
j35om040h.eps
j35om040h.eps