Cleaning instructions…continued – American Energy Systems MagnuM T40 User Manual
Page 16
![background image](/manuals/733789/16/background.png)
CLEANING INSTRUCTIONS…continued
WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING OR SERVICING THIS
UNIT. THE STOVE MUST BE TURNED OFF AND COOLED BEFORE USING THE RAKE
HANDLE.
II. HEAT EXCHANGER:
This stove is designed with a built-in heat exchange tube rake.
The ash rake handle is located on the front of the stove and is
moved backwards and forwards several times to remove the
buildup of ash. After cleaning, push the rake handle in until
it stops.
III. COMBUSTION BLOWER:
Over the course of the heating season dust and ash may collect on the blades of the combustion blower.
Periodically they should be inspected and vacuumed clean. The combustion blower is accessed by
removing the stove’s right side panel and then removing the inspection caps or the exhaust manifold cover
(See figure below). Never operate the stove without the inspection cap or manifold cover in place.
NOTE: THE EFFICIENCY AND PERFORMANCE OF THIS STOVE DEPENDS GREATLY ON
REGULAR CLEANING, SERVICING AND MAINTENANCE. FAILURE TO PROPERLY
CLEAN AND SERVICE THIS STOVE AS INDICATED IN THIS MANUAL MAY CAUSE A
MALFUNCTION OR HAZARDOUS OPERATION OF THIS STOVE.