American Energy Systems MF3650 Exhaust Blower User Manual
American Energy Systems Kiln
![background image](/manuals/733761/1/background.png)
F:\AESBusinessSystems\AES Technical\Piece part instructions\MF3650 Exhaust Blower 2-
speed.doc
MF3650 Exhaust Blower 2-speed
All Magnum units that may require extra CFM when installed (see below)
1. It provides more air movement through the unit when combustion air and venting
configurations are limited
2. It is usually added to stoves that are in areas of higher altitude to assist in proper
combustion.
3. Can or should be used on installations that have longer horizontal exhaust runs.
4. Adapts the unit for new high ash content fuels that are emerging in the market.
5. Can be used as a replacement for CF3542 or MF3542.
6. Use jumper wires as needed.
• Turn off power on control panel and unplug from the power supply.
• Disconnect the exhaust blower leads from the wire harness make sure when pulling off
wires that you use pliers by the end of the terminals, so you don’t pull out the wire from
the ends.
• Remove existing exhaust blower.
• Remove existing exhaust tube from the
exhaust blower being replaced.(save the
#8-tek screws for later use)
• Clean the rectangle outlet of the exhaust
tube of any old high temp silicone.
• Place a 1/8” bead of high temp silicone
on the rectangle outside edge of the
exhaust tube.
Back side of blower
Front of blower
Connection Diagram
Wht-Common
Blk-High
Red-Low