beautypg.com

Control panel/thermostat hook-up – American Energy Systems MagnuM T40 User Manual

Page 11

background image

CONTROL PANEL/THERMOSTAT HOOK-UP

WARNING: ALWAYS DISCONNECT POWER CORD DURING ANY ELECTRICAL
OPERATION.

1. Remove control panel from protective packaging.
2. Connect the one way molex plug to the control panel, do not pull on the wire harness inside the

stove.

NOTE: Use only a low voltage mercury or bi-metal thermostat switch. (No power required on
thermostat)
NOTE: If you are not going to use the thermostat function then skip steps #3 - #8 and go to step #9.

3. Locate the thermostat on a wall six (6’) to (10’) feet away.
4. Route the wires into the stove near where the AC power cord enters.
5. Pull the thermostat wires through to the control panel cut-outs.
6. Remove the factory installed jumper from the upper position. (see details below)
7. Connect the thermostat wires to the two terminals on the back of the control panel. When the

room temperature drops below the thermostat setting, the thermostat switch will close, allowing
the stove to operate at the medium or higher setting. When the room temperature matches the
thermostat setting, the thermostat switch will open, allowing the stove to operate at the low
setting.

8. Locate the control panel into the side panel cut-out and secure with four (4) #7 x ½ Phillips screws

(supplied). Do not over tighten.

9. The stove is now ready for operation. Refer to the OPERATING INSTRUCTIONS.

Note: The thermostat function of the stove will cycle with the room temperature when the “Fuel
Feed Control” is set at a medium or higher setting.