VERTICAL INSTALLATION
GUIDELINES ON CONNECTING TO AN EXISTING FACTORY-BUILT CHIMNEY:
1. Inspect the chimney for the presence of creosote, soot or other combustible deposits, and blockage
or obstructions. Thoroughly clean the chimney and remove any obstructions.
2. Thoroughly inspect the chimney for soundness, proper clearances and presence of all necessary
parts, including a chimney cap, prior to making the connection.
3. This stove may be connected to an existing ceiling-mounted factory-built chimney with a diameter
of 4, 6, or 8 inches.
4. Use a 3-4”, 3-6” or 3-8” Pellet Vent to Chimney Adapter provided by the pellet vent manufacturer.
5. Use only listed 3 inch Type PL pellet vent pipe between the stove and the chimney.
6. Follow the pellet vent manufacturer’s instructions to assemble the vent pipe and make the
connection to the chimney.
EXISTING
FACTORY-BUILT
NEW
INSTALLATION
CHIMNEY
INSTALLATION
NOTE: THE PIPE LENGTHS SHOWN ARE FOR REFERENCE ONLY. YOUR ACTUAL PIPE LENGTHS MAY VARY.
SINGLE WALL PIPE SHALL NOT BE USED FOR ANY INSTALLATION.
PLEASE FOLLOW THE PIPE MANUFACTURER’S INSTRUCTIONS AND LOCAL
BUILDING CODES FOR THE CLEARANCE TO COMBUSTIBLES REQUIRED FOR
INSTALLATION OF THE VENT PIPE BEING USED.