American Energy Systems RP2062 DC Wire Harness User Manual
Wire harness assemble dc part #rp2062
F:\AESBusinessSystems\AES Technical\Piece part instructions\RP2062 Wire Harness DC.doc
Wire Harness Assemble DC
Part #RP2062
for Models Baby DC, Win DC, Essex DC & T40 DC
• Unplug unit
• Open both side panels.
• Remove existing wire harness.
• Attach the following:
o
Control Board
molex connector (6 prong and 8 prong)
o
Exhaust
Fan
blue
wire
to
red
lead purple wire to blue lead
(depending on style fan white to blue wire black to purple wire)
o
High Limit Snap Disk
two orange wires to both leads
o
Vacuum Pressure Switch
two grey wires to both leads
o
Proof of Fire Snap Disk
two brown wires to both leads
o
Auger Motor
yellow wire to top terminal w/ red dot (+) yellow/black wire to
bottom
terminal
(-)
o
Room Air Fan
pink wire to red lead one purple double to black lead
o
Electrical
Plug
molex
connector
to
power
supply
(5
prong)
o
Igniter
red/white
wire
to
one lead white wire to one lead
(these are not plugged into anything if there is not an igniter)
N.O.
3
N.C.
2
COM
1
Attach one grey wire to ‘Com
1’ and one grey wire to ‘NO 3’.
Attached hose to back
connection ‘L’.
RT080 World Magnetics
Vacuum Pressure Switch
Attach one grey wire to ‘Com 1’
and one grey wire to ‘NO 3’.
Attached hose to bottom connection
‘P2’.
RT080 Clark Controls
Vacuum Pressure Switch
N.O.
3
N.O.
2
N.O.
1