Optional 12 volt battery back-up – American Energy Systems MagnuM T40 User Manual
Page 12

OPTIONAL 12 VOLT BATTERY BACK-UP
WARNING: ALWAYS DISCONNECT POWER CORD DURING ANY ELECTRICAL
OPERATION
Note: Never use an unsealed battery
1. Disconnect the 110 volt AC power before connecting the 12 volt battery.
2. Determine the location for the 12 volt battery and obtain the proper length and type of wire (Use
18 gauge stranded wire)
3. Drill and install ½” conduit where passing through a wall or floor.
4. Connect a red 18 gauge wire to red positive (+) battery terminal on the stove
5. Install a 4 amp inline fuse on the red positive wire near the stove.
6. Connect a black 18 gauge wire to black negative (-) battery terminal on the stove.
7. Pass wires through the conduit to battery location. Allow enough wire length between battery box
and exterior wall for a drip loop to prevent moisture from reaching terminals. (see diagram)
8. Connect the red positive (+) lead to the positive (+) battery terminal.
9. Connect the black negative (-) lead to the negative (-) battery terminal.
10. Reconnect the 110 volt AC power. The stove is now ready for 12 volt back-up and will switch
automatically to 12 volt operation when AC power is lost. When AC power is restored, the stove
will automatically switch back to AC power and recharge the battery.
NOTE: THE SELF IGNITER WILL NOT START THE STOVE IN THE DC POWER MODE.
(12v Battery Back-up)
STARTING THE STOVE IN DC POWER MODE ( 12v Battery Back-up)
1. Clean out and dump the firepot (See note at top of page 13)
2. Pull the air damper rod out approximately ¾
3. Turn the “Fuel Feed Control” to the 3
rd
position
4. Open the door and add approved fire starter to ½” of pellets in the firepot and light the fire starter.
Once the fire starter is burning freely, close the door.
5. When the pellets are burning well, press the “On/Off” switch to the “On” position.
6. Let the fire continue to build approximately 1 minute, then push the “Start” button.
+ DENOTES POSITIVE
- DENOTES NEGATIVE