American Energy Systems MagnuM Baby Countryside User Manual
Corn/ biomass / wood pellet stove, Magnum baby countryside, Owner’s manual
1
Magnum Baby Countryside
Corn/ Biomass / Wood Pellet Stove
BURNING STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE, BODILY INJURY OR EVEN DEATH.
IMPORTANT: Always contact your local dealer/installer with questions before contacting the factory.
When you call have your serial number, purchase date, who installed the unit and a list of questions.
AMERICAN ENERGY SYSTEMS, INC. GRANTS NO WARRANTY, IMPLIED OR
STATED, FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND
ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
AMERICAN ENERGY SYSTEMS, INC. -150 Michigan Street SE - HUTCHINSON, MINNESOTA 55350
Web
Site:
www.hearthdirect.com
NOTE: THESE INSTRUCTIONS MUST BE SAVED for future reference
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET
Rev. date 6/4/07
9 When installing your Magnum Corn/ Biomass / Wood Pellet stove, particular attention needs to be made
in regards to fire protection. If the unit is not properly installed, a house fire may result. For your safety,
follow the installation and operation instructions provided, and if a question arises contact local building or
fire officials about restrictions and installation requirements in your area.
9 Read the operations and fuel section of this manual before plugging in your unit.
9 Always unplug the unit before attempting any service work.
9 Do not connect the unit to a chimney flue already serving another appliance.
9 When installing the chimney pipe to the unit, it is important to remember that the unit operates on a
negative pressure and the chimney on a positive pressure. All chimney connections, elbows and fittings
must be airtight. (proper venting practices must be followed. Consult with a venting professional)
9 Ashes must be disposed of in a metal container with a tight fitting lid.
9 All minimum clearances to combustibles must be followed.
9 The Magnum Corn/Biomass/Wood Pellet Stove is tested for operation with wood pellets with an ash
content of no more than 2% and Corn with a moisture content from 10-14 percent. It is recommended
that wood pellets with an ash content of 1% or less be used for efficient operation of this unit. Higher
ash content fuels will require additional maintenance and service. For use with wood pellets, cherry
pits, olive pits or other pelletized Biomass fuel. Corn with 11-12 percent moisture is ideal.
9 It is important to use fuel that is clean, dry and consistent. Make sure that your supplier is giving you
the same fuel each time that you purchase. It is recommended that you purchase your entire heating season
supply of fuel at one time so that the fuel will be the same.
9 A voltage surge protector or ground fault outlet is required for this unit. The electrical component
warranty will be voided if surge protection is not installed before operating this unit.
9 A grounded outlet must be provided with proper polarity. A constant 115 volt (12volt on DC
models), 60 cycles must be provided for proper operation or the warranty of this appliance will be
forfeited.
9 Special attention needs to be taken to clean out the top heat exchangers of this unit on a regular
basis. The fly ash settles on the heat exchangers and must be cleaned off to keep the unit operating
properly. Check for plugging every two-four weeks or when needed.
9 If unit is not operated for extended periods of time (like summer) unplug the unit and disconnect the
battery to assure long life of electrical components.
OWNER’S MANUAL
Installation – Operation – Maintenance Instructions
Document Outline
- Back Wall
- SHELLED CORN (11-12 percent moisture recommended)
- When you receive your Magnum appliance, be careful to inspect all parts and components to make sure that nothing was damaged or lost in shipment. If there was shipping damage, be sure to report it to your Magnum reseller, or the shipping company that delivered your unit. Freight damage claims must be made to the Freight Company immediately. If parts are missing contact your local Magnum reseller or contact the factory right away. Your satisfaction is our top priority.
- MAGNUM BABYCOUNTRY SIDE APPLIANCES REPLACEMENT PARTS LIST
- MODEL NAME/DESCRIPTION
- BC2500
- Magnum Baby Countryside Auto-Light system, complete assembly
- BC2000
- Igniter, Baby Countryside
- RP2004DC3
- Magnum Baby Countryside,T40, Essex Control Board (DC)
- RP2015
- Magnum Baby Countryside,T40, Control Board Super (DC)
- RP2007
- Magnum Baby Countryside Circuit Board (Digital electronic board)
- RP2010
- Magnum Baby Countryside,T40, Essex DC Power Supply RPS-300
- RP2020
- RP2022
- Magnum Baby Countryside,T40 AC 2 rpm Auger Motor
- RP2025
- Magnum Baby Countryside,T40, Essex DC Combustion (draft)Blower Motor (Motor Only)
- RP2026
- T40, Essex DC Combustion (draft) Blower Motor support plate
- RP2027
- T40, Essex DC Combustion (draft) Blower (complete assembly)
- RP2030
- Magnum Baby Countryside,T40 AC Combustion Blower (complete assembly)
- RP2035
- Magnum Baby Countryside,T40, Essex, Avent DC Room Fan
- MF3541
- Magnum Baby Countryside,T40 AC Convection blower
- MF3537
- F-110 N/O POF Switch (interchangeable with F-140 & F-150 auto reset)
- RP2050
- L-225 N/C Switch (manual reset) Magnum Baby C/S, T40 / Essex
- RT080
- Magnum Baby Countryside,T40, Essex, Hopper Pressure Switch
- RP2063
- RP2062
- Magnum Baby Countryside DC unit Wire Harness assembly
- RP2075
- Magnum Baby Countryside, Essex Gold Door Finish (only) (re-finish gold door)
- RP2076
- Magnum Baby Countryside, Essex Gold Door (complete door)
- RP2077
- Magnum Baby Countryside, Essex Black Door (complete door)
- BC3525
- Gold Grill assembly (separate)
- BC3555
- Nickel Grill Assembly (separate)
- RP2078
- Magnum Baby Countryside Nickel Door (complete door)
- BC2600
- Magnum Baby Countryside Wood Firepot
- BC2700
- Magnum Baby Countryside Corn Firepot
- RP2087
- Magnum Baby Countryside, Essex Black Trivet (separate)
- RP2088
- Magnum Baby Countryside, Essex Gold Trivet (separate)
- RP2089
- Magnum Baby Countryside, Essex Nickel Trivet (separate)
- RP2090-P400
- Magnum Baby Countryside, T40, Essex, Avent Auger Assembly
- RP2091
- Auger Bushing (set)
- P1155
- Heat Exchanger Rake Handle
- RP2093
- Damper Spring Handle
- RP2096
- Neorprene Hose ¼” ID Hose (per foot)
- RP2097
- Door Handle Assembly
- RP2098
- Magnum Baby Countryside / T40 / Essex Arched Glass (w/gasket)
- RP2099
- Glass Gasket (separate) per foot (specify T40 or Essex)
- RP2100
- Door Gasket (separate) per foot (specify T40 or Essex)
- P1315
- 4 ¾” diameter draft blower blade (located in draft blower housing)
- P1316
- 3” diameter blade for DC Combustion (draft) blower