beautypg.com

Redundant power supplies – D-Link DES-7200 User Manual

Page 46

background image

44

Redundant Power Supplies

Redundant Power Supplies

D-Link redundant power supplies (RPS) are designed to conform to wattage requirements of D-Link switches. These external
RPS are enclosed in solid metal cases with sockets to AC or DC power sources on one end and the connectors to the switch’s
internal power supply on the other end.

SWITCHES

Redundant Power Supplies

Model

Output Power

Input Power

Input

Frequency

Form Factor

Over Current

Protection

DPS-200

60-Watt

90 to 264VAC

AC Power Source

47 to 63Hz

Solid Metal Case

Yes

DPS-500

140-Watt

90 to 264VAC

AC Power Source

47 to 63Hz

Solid Metal Case

Yes

DPS-500DC

140-Watt

-36 to -72VDC

DC Power Source

47 to 63Hz

Solid Metal Case

Yes

DPS-600

500-Watt

90 to 264VAC

AC Power Source

47 to 63Hz

Solid Metal Case

19-inch Rack-Mount, 1U

Height

Yes

Redundant Power Supply Chassis

Model

No. of RPS Slots

Form Factor

Supported RPS

DPS-800

2

19-inch Rack-Mount, 1U Height

DPS-200; DPS-500; DPS-500DC

DPS-900

8

19-inch Rack-Mount, 5U Height

DPS-200; DPS-500

Redundant Power Supply Accessories

Model

Description

Supported RPS

DPS-CB400

4-Meter Extension Power Cable

DPS-200; DPS-500; DPS-500DC