И. CFM Select Configuration Taps

The CTM Select taps are used by installer to configure system. The
ICM2 is capable of discerning wave shapes on some of its input?
and uses this capability to modify its operation to a pre­
programmed table of airflows and can be modified in response to

other

inputs

Such as the need for de-humidification.

I. 1CM2 Control Power

The ICM2 control power is supplied from R circuit through
printed-circuit runs to motor control connector pin 6|, through
rnotor control harness to motor. The C side of low-vpltagc control
power circuit is connected by printed-circuit runs to motor
connector pins 4 and 5, then through motor control harness to
motor,

J.

Low-Voltage Circuit

Fusing and Reference

The low-voltage circuit is fused by a board-mounted 5-amp

automotive-type fuse placed in series with transformer SEC2 and

R circuit. The C circuit of transformer is referenced to chassis
ground through a printed-circuit run at SECl connected to metal

standoff marked GROUND SCREW REQUIRED,

NOTE:

A ground screw must be in place or erratic motor

operation can result.

K. Transformer, Motor, and Electric

Heater Power

Connections

The high-voltage (230-vac) power input to board is provided
through electric heater connector pins 7 and 9. The high voltage is
then connected through printed-circuit runs to motor power con-

A94079

ICM2 Motor

nections Ml and M2 and transforníer power connections T1 and

T3. Transformer connection T2 is a dummy terminal used for
unused primary power lead. The transformer Secondary conriec-
tions are made at SECl and SEC2 connectors.

IV, EASY SELECT CONFIGURATION TAPS

The Easy Select taps are used by installer to configuire system. The
ICM2 uses selected taps to modify its operation to a pre­

programmed

table of airflows. Airflows are based on system size

or mode of operatibh and thosd airflows arc modified in response
to other inpüts stich as the need for de-humidifícation. (Sec Fig. 6.)

The FK4B Ran Coil must be

configured

to operate properly with

system components with which it is installed. To successfully
configure a basic system (see information printed on circuit board
located next to select pins), move the 5 select wires to pins which

match components used,

A.

Auxiliary Heat Range

The installer must select the auxiliary heat airflow approved for
application with kw size heater installed. If no heater is installed,
skip this step. Each select pin is marked with a range of heaters for

which airflow (also marked) is approved. The heater installed must
fall within range selected for safe and continuous operation. It is
appropriate to mention that airflow marked is the airflow which
will be supplied in emergency heat mode and heating mode on air
conditioners when electric heat is primary heating source. To
ensure safe heater operation in heat pump heating mode when