Unit functions, A. transformer, B. electric heat – Bryant FA4A User Manual

Page 25: Table 7—electric, C. acces^órics, D. blower, Heater stage limiting

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

A U G / 1 4 / 2 0 0 8 / T H U 0 3 : 5 1

UTC TECH PUB

F A X N o , 3 1 7 2 4 0 5 6 6 2

7 0 2 5

A94127

Fig. ; £ 2 — P i ' i n t e d - C i r ' c u i t Board (PCB)

tl.

3. A fuse is used to protect low-voltage transformer and PCB,

4. AUX+ and AUX- are connections for air.4 conditioning

accessories (EAC, humidifier, etc.).

5- FI, F2, HI, and LO arc connections for indoor fan.

6, The 9-pin receptacle connects heater package wiring har­

ness.

7, SECl and SEC2 are used to connect secondary side of

transformer to PCB. SECf is connected to equipment

ground,

UNIT FUNCTIONS

A. Transformer

NOTE:

Terminals Tl, T2 (^if used), and T3 are wired to primary

or hi^h side of tr^nsfqmer.'The ^08-v tqrininal ‘(br blue wire'jf
transformer Has‘ primary lfeads) is on

2D8^^^applica-’'"

tjons, The 230-v tcoiimal (t;>r red witt) i$ iisAa^on'i’3'tpr 23Q-v

applications, T2 is a dummy terminal.

'i ■'■■i >

B. Electric Heat

NOTE: When troubleshooting dements, position thermostat to

emergency heat. Wait approximately 12 minutes for all elements to

come On,

1. When thermostat calls for electric heat, a 24-v signal is sent

to PCB through W2T, The PCE energizes first stage of
electric heat.

TABLE 7—ELECTRIC

2. The first 2 stages come on if WZT and Y are energized at

the same time. After each 10 minutes W2T iiS energized,
another stage of electric heat is energized.

3. As W2T is de-energized, electric heat, stages down in S

minute steps with the exception of first step. The first step
will be on only half as long as -it was prior to W2T
de-energizing.

- y - . ,

4. When W2T is energized by itself, JWl is cut, and an

outdoor thermostat is used and is open, staging is limited as

in Table 7,

5. When bAlh. W3 and W2T are energized without JWl being

cut'or with outdoor thermostat closed, system operation

.! stagesdieat up to maximum level if signal is energized for

ргоры gpiouhi:_pf .time,

6/ If'órilyFW3 is energized, there is no effect on PCE, No heat

.iS'^nergiicid..

C. Acces^Órics

Terminals AU^-t- and AUX- áre energized with 24 vdc when fan
is energizetl. The accessbry kit KFAIROIOIACR is used to
connect'aii EAC or'humidifier.

NO.TjE: "Loads cannot^be connected directly to AUX+ and AUX".

Us,e the specified kit only.

D. Blower

1. Blower On Dclay—To optimize comfort, there is a 30-sec

blower on delay in heat pump heating mode only.

HEATER STAGE LIMITING

HEATER PART NO.

STAGES (KW OPERATING)

W2T Only (JW1 cut)

W

2

T and W3

Heater Stage

1

2

3

4

KPAFH22Q1H1Q

10 kw Non-Fuaed

3

6

9

9

KFAEH2301H15

15 kw Fused

3

8

11

15

KFAEH2401H20

ЙО kw Fused

6

10

15

20

-

25

-