MOTOR SPECIFICATIONS AND ELECTRICAL REQUIREMENTS
This saw is designed to use a 3450 RPM motor only.
Do not use any motor that runs faster than 3450
RPM. It is wired for operation on 110-120 volts, 60
Hz.,
Alternating
current.
IT
MUST
NOT
BE
CONVERTED TO OPERATE ON 230 VOLTS.
The Black and Red motor leads are connected to
quick connect tabs “A” and “B” on terminal board.
WARNING: Do not change any of these connec
tions with current on.
CAUTION: Do not use blower or washing machine
motors or any motor with an automatic reset
overload protector as their use may be hazardous.
For replacement motor refer to parts list in this
manual.
CONNECTING TO POWER SOURCE OUTLET
This saw must be grounded while in use to protect
the operator from electrical shock.
If power cord is worn or cut, or damaged in any way,
have it replaced immediately.
If your saw is for use on less than 150 volts it has a
plug that looks like below.
Plug power cord of fully assembled saw into 110
120V properly grounded type outlet protected by a
15-amp. time delay or Circuit-Saver fuse or circuit
breaker.
IF YOUR ARE NOT SURE THAT YOUR OUTLET IS
PROPERLY GROUNDED, HAVE IT CHECKED BY
A QUALIFIED ELECTRICIAN.
WARNING;
DO
NOT
PERMIT
FINGERS
TO
TOUCH THE TERMINALS OF PLUG WHEN
INSTALLING OR REMOVING THE PLUG TO OR
FROM THE OUTLET.
WARNING: IF NOT PROPERLY GROUNDED THIS
POWER TOOL CAN INCUR THE POTENTIAL
HAZARD OF ELECTRICAL SHOCK PARTICU
LARLY WHEN USED IN DAMP LOCATIONS, IN
PROXIMITY TO PLUMBING, OR OUT OF DOORS.
IF AN ELECTRICAL SHOCK OCCURS THERE IS
THE POTENTIAL OF A SECONDARY HAZARD
SUCH AS YOUR HANDS CONTACTING THE
SAWBLADE.
This saw is equipped with a 3-conductor cord and
grounding type plug which has a grounding prong,
approved by Underwriters’ Laboratories and the
Canadian
Standards
Association.
The
ground
conductor has a green lug and is attached tothetool
housing at one end and to the ground prong in the
attachment plug at the other end.
This plug requires a mating 3-conductor grounded
type outlet as shown.
If the outlet you are planning to use for this saw is of
the two prong type DO NOT REMOVE OR ALTER
THE GROUNDING PRONG IN ANY MANNER. Use
an adapter as shown and always connect the
grounding lug to a known ground.
It is recommended that you have a qualified
electrician replace the TWO prong outlet with a
properly grounded THREE prong outlet
A temporary adapter as shown below is available for
connecting plugs to 2-prong receptacles. The green
grounding lug extending from the adapter must be
connected to a permanent ground such as to
a
properly grounded outlet box.
A temporary adapter as illustrated is available for
connecting plugs to 2-prong receptacles. The
temporary adapter should be used only until a
properly grounded outlet can be installed by
a
qualified electrician.
GROUNDING LUG
MAKE SURE THIS IS
CONNECTED TO A
KNOWN GROUND
2-RRONG
RECEPTACLE
ADAPTER
WARNING:
THE
GREEN
GROUNDING
LUG
EXTENDING FROM THE ADAPTER MUST BE
CONNECTED
TO
A
PERMANENT
GROUNC
SUCH AS TO A PROPERLY GROUNDED OUTLEl
BOX. NOT ALL OUTLET BOXES ARE PROPERL1
GROUNDED.
If you are not sure that your outlet box is proper!)
grounded, have it checked by a qualified electrician
NOTE: The adapter illustrated is for use only if yoi
already
have
a
properly
grounded
2-prong
receptacle.
The use of any extension cord will cause some loss
of power. To keep this to a minimum and to preven
over-heating and motor burn-out, use the table
below to determine the minimum wire size (A.W.G.'
extension cord. Use only 3 wire extension cords
which have 3 prong grounding type plugs and 3
pole receptacles which will accept the plug on the
saw.
■
■ ,.
■
The motor must rotate COUNTERCLOGKWfSi
When viewed from the shaft end.
1 H.P. MOTOR 1ie-12S¥
Extension Cord Length Wre Size A.W.Q.
U p t o S O F t . . . . . . . . . . . . . . . . . 1 4
5 0 t o t o o F t . . . . . . . . . . . . . . . 1 2
■'''i00-'''200Ft.,'
T O ' ; / ■ ■
2 0 0 - 4 0 0 F t . ___ _. . . . . . . . . . 8 .................