beautypg.com

Fig. 32 — 38cq refrigerant flow diagrams – Carrier 38CQ User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

ACCESSORY

FILTER DRIER

SUCTION

SERVICE

PORTAT

SERVICE
VALVE
(HTG CYCLE)

OUTDOOR

COIL

SUCTION
SERVICE
PORT

LIQUID LINE

SERVICE

PORT AT

SERVICE
VALVE

(CL6 CYCLE)

DISCHARGE

SERVICE

PORT AT

SERVICE

VALVE

(HTG CYCLE)

ACCESSORY

FILTER DRIER

BYPASS TYPE

ACCURATOR (PERMITS FLOW
IN EITHER DIRECTION)

STRAINERS

-WAY

valve

ACCUMULATOR

iUNIT PIPING

HEATING CYCLE

COOLING CYCLE

Fig. 32 — 38CQ Refrigerant Flow Diagrams

SUCTION

SERV^ICE

PORTAT
SERVICE

VALVE
(CLG CYCLE)

Fig. 33 — AccuRater^'^ (Bypass Type) Components

6. Clean piston refrigerant metering hole.
7.

Replace retainer 0-ring before reassembling

bypass type AccuRater. Carrier O-ring part no.
is99CC501052.

LIQUID LINE STRAINER (protects AccuRater)
made of wire mesh is located in the liquid line
inside 38CQ unit behind liquid line service valve.
Liquid line is belled and sweat connected where
strainer is located. If strainer is plugged, unsweat
belled liquid line connection and replace strainer.

Compatible Fitting Repair

LEAKING MECHANICAL CONNECTION -
Frontseat outdoor section service valves and relieve
refrigerant pressure in tubing. Back locknut off
Carrier Compatible Fitting onto tube. Cut fitting
between threads and seal ring bead shown in

Fig. 34. Remove tubing section remaining in
threaded portion of fitting. Discard locknut.

Clean, flux, and insert new tube end into

remaining portion of Carrier Compatible Fitting.

Wrap valve base in wet rag. Heat and apply

low-temperature solder (450 F).

LEAKING SWEAT CONNECTION - Frontseat
service valves and relieve refrigerant pressure in
tubing. Clean and flux area around leak and apply
low-temperature solder (450 F).

Evacuate or purge indoor coil and tubing

system. Add refrigerant charge (seb charging
instructions).

Leaking Flare Connection

— Cut and reflare 3/8-in.

system liquid line.

I,

Fig. 34 — Carrier Compatible Fitting

16