regulation adjustment Speed

Default = 9.5 (byp Mode)

While in this step, the regulator symbol

will be flashing at the top

of the console display. This step allows you to regulate the speed of the

pressure regulating valve to accommodate different application needs.
Operating conditions may necessitate a higher or lower response

speed for the regulating valve. To change the response time number,

simply use the Plus key and Minus key to increase or decrease

the number. Any number between 0.0 and 9.9 can be selected. The

first digit sets the speed for the coarse adjustment in relation to a large

percentage outside of the target application rate. The second digit sets

the speed for the fine tune adjustment in relation to a small percentage

close to the target application rate.

9.5

Coarse adjustment

Fine adjustment

If your system is plumbed in a bypass mode, the valve speed number

of 9.5 works very well in most applications.
If your system is plumbed in a throttling mode, start with a valve speed

number of 3 and adjust the number according to your application

requirements. Low flow situations will require a slower response time.

Adjusting agitation volumes to accommodate the regulating valve to

work in a more fully open position allows for a faster response time,

with little to no searching.
To accept this value and advance to the next step, press the Program

key .
NOTE: This speed value can be adjusted to optimize system

performance. If you notice that the valve seems to “search” for

the programmed application rate by cycling the pressure up

and down continuously, reduce the number until the “searching”

is minimized or eliminated. Conversely, a higher number will

increase the valve response speed and speed up the rate of

adjustment.

Control Valve type

Boom Control Valve Type: 2-Way/3-Way

Default = 2 Way

While in this step, the regulator symbol

will be flashing at the top

of the display. The programmable information (2 Way or 3 Way) will be

displayed at the left in the console display.
This programming step is used to distinguish the type of on-off boom

control valves you have on your system. There are two types of valves

that can be used, 2-way control valves or 3-way control valves.
A 2-way control valve is simply an on/off valve. Flow is either directed

to the boom section(s) or it is blocked or diverted away from the booms.

A 3-way control valve is know as a by-pass valve. Flow continuously

passes through this valve. When the valve is activated (on), flow is

directed to the boom section(s). When the valve is not activated (off),

flow is directed through a bypass port, back to the supply tank.
If you are using the 3-way type of boom control valves in your system,

change the value using the Plus key or Minus key .

Press the Program key to accept the value and advance to the next

programming step.
If the default value is correct, press the Program key to accept the

value and advance to the next programming step.
NOTE: If using 3-way, bypass boom control valves, refer to the

instruction manual of the valve you are using for proper

calibration instructions.