beautypg.com

Connect step 2 - making the connection, E sprayer control – TeeJet 844-E Sprayer Control User Manual

Page 15

background image

11

98-70006-ENUS R4

844-E Sprayer Control

Connect Step 2 - Making the Connection

Now, extend the cable leads to the Flow meter or Pressure Sensor, and Wheel Sensor or Radar Sensor to the furthest component. Select the

appropriate lead and connect to this component. Run the cable to the other component, taking care to safely secure the cable along the route.

Refer to the diagram on page 10.
Repeat this procedure with the cable leads to the Pressure Regulating Valve and the Boom Control Valves. Refer to the chart below when

attaching the boom section wires. T-tap connectors must be attached to the +12vDc and ground wires to connect them to the boom control valves

(when using ball valves), which should be evenly distributed across the two.
If both the flow meter and pressure transducer are not used simultaneously, there will be one extra connection on the cable. Simply tie this part of

the cable back as it will not be used.
When all connections have been made, connect the large plug into the side of the Control Console.
Figure 15: Console Connector

Console Connector

Pin No.

Wire Color

Signal Name

B

White

Section 1

C

Brown

Section 2

D

Green

Section 3

E

Yellow

Section 4

F

Gray

Section 5

R

White

Flow Signal

S

White

Pressure Signal

T

White

Speed Signal

V

Brown

Power Out

a

White

Regulation Valve (+)

b

Brown

Regulation Valve (-)

c

Blue

+12 VDC

d

Blue

Pink

Ground Free End (Valves)

e

Red

Black

+12 VDC Free End

Figure 16: Power Connector

Power Connector

Pin No.

Wire Color

Signal Name

1

Brown

+12 VDC (Computer)

2

Blue

+12 VDC (Valves)

3

Yellow/Green

Ground

Figure 17: Speed Sensor Connector

Speed Sensor Connector

Pin No.

Wire Color

Signal Name

A

Brown

Power Out

B

White

Speed Signal

C

Green

Ground