844-E Sprayer Control

User program tip

User Programmable Tip

Default = 0.00
While in the User Programmable Tip step, the tip indicator arrow

will be flashing above the

P

tab at the bottom of the display.

In some cases you may find that nozzles other than those pre-

programmed for the 844 Sprayer Control will need to be used. If

one of the eleven pre-programmed tips do not meet your needs, this

programming step allows the user to manually program a tip.
Use the Plus key or Minus key to adjust flow rate in US

Gallons Per Minute (Liters Per Minute) {Imperial Gallons Per Minute}

at 40 psi (2 bar). Pressing the Plus key and Minus key

simultaneously will clear the value to zero. To accept the value, press

the Program key to advance to the next programming step.
The flow rate information for the tip is only used to calculate the

pressure reading for flow based controls. With non-linear tips, the

calculation would be incorrect. Therefore we recommend a “0.00”

setting for non-linear tips so that the pressure will read “0” at all times,

instead of an inaccurate pressure. Non linear tips should not be used

with pressure based controls. Pressure based controls use the tip flow

rate information to adjust the pressure to achieve the right application

rate based on the size of the tips. With non linear tips, there is no way

for the controller to accurately calculate what the pressure should be at

various speeds.
WARNINg: If the user is using tips other than the TeeJet®‚ VisiFlo®

brand, the corresponding colors may not match. In this

case, the user should determine the flow rate of the tip

being used at 40 psi (2 bar), and enter this flow rate as the

programmable tip.

NOTE: The flow rate will be automatically displayed at 40 psi (2 bar).

This pressure must be used for determining your tip’s flow rate.

Actual operation pressure is not important.

When the correct nozzle flow rate has been entered, advance to the

next programming step by pressing the Program key .

pressure regulation

Pressure Regulation Mode

Default = byp (By-pass for US, trF, I

N

P

, and Si Modes)

Default = thr (Throttling for nh3 Mode)

While in the Pressure Regulating Mode step, the regulator symbol

will be flashing at the top of the console display.
This step tells the 844 where the regulating valve has been plumbed.

Once set correctly, this value should not change unless the regulating

valve is physically moved to a new point in the plumbing. For more

information on plumbing refer to pages 2 and 3 of this manual.
The default value “bYP” indicates that the pressure regulating valve

is plumbed in the bypass line. In most situations, especially total flows

below 4 US GPM (15 l/min) {3.3 Imperial GPM}, this is the preferred

installation position. If the default is correct, press the Program key

to accept the value and advance to the next step.
NOTE: When programmed in the bypass mode, with the controller in

“MAN” mode, the pressure regulating valve should close when

the Plus key is pressed, and open when the Minus key

is pressed.

The pressure regulating valve can be located in the supply line

between the flow meter and the boom control valves. If you will be

locating the pressure regulating valve in this position, use the Plus key

or Minus key to change the value to tHr (Throttling Mode).

By doing this, you have reversed the polarity that the console uses to

control the regulating valve.
NOTE: When programmed in the throttling mode with the controller

in “MAN” mode, the valve should open when the Plus key

is pressed and close when the Minus key is pressed.

Press the Program key to advance to the next step.