Reznor R6GN Unit Installation Manual User Manual
Page 27

27
5 HP
lo
W S
ta
t
Ic
DRIVE
(F
A
CT
OR
Y
SETTINGS)
Motor
Shea
ve
P
osition
External
Static
Pressures
(Inc
hes
W
ater
Column)
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.00
1.10
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
Fully Closed
6250
1218
3.79
6000
1219
3.63
5650
1221
3.42
1/2 T
ur
n
Open
6325
1196
3.73
6050
1197
3.58
5750
1198
3.45
5375
1200
3.31
1 T
ur
n
Open
6400
1174
3.66
6100
1175
3.51
5850
1176
3.36
5500
1177
3.26
5100
1178
3.20
1.5 T
ur
ns
Open
6225
1157
3.52
5950
1158
3.37
5650
1159
3.23
5300
1160
3.08
4875
1161
2.95
2.0 T
ur
ns
Open
6350
1139
3.52
6050
1140
3.38
5800
1140
3.23
5450
1141
3.10
5100
1142
2.90
4650
1144
2.70
2.5 T
ur
ns
Open
6200
1121
3.33
5875
1122
3.19
5625
1123
3.05
5225
1124
2.91
4850
1125
2.74
3.0 T
ur
ns
Open
6300
1102
3.26
6050
1103
3.13
5700
1104
3.00
5450
1105
2.86
5000
1106
2.71
4600
1107
2.58
3.5 T
ur
ns
Open
6150
1085
3.07
5900
1085
2.95
5550
1086
2.82
5250
1087
2.68
4800
1088
2.51
4.0 T
ur
ns
Open*
6300
1066
3.10
6000
1067
2.88
5750
1067
2.76
5400
1068
2.64
5050
1069
2.50
4600
1070
2.30
4.5 T
ur
ns
Open
6100
1048
2.92
5800
1049
2.75
5675
1049
2.61
5250
1050
2.49
4825
1051
2.36
5.0 T
ur
ns
Open
6200
1028
2.84
5900
1029
2.73
5600
1030
2.61
5600
1030
2.45
5100
1031
2.33
4600
1032
2.21
5 HP HIGH S
ta
t
Ic
DRIVE
-
OPTIONAL
KIT
(Ref
er
to
T
ec
hnical
Data
Sheet
for
appr
oved
accessor
y
kits)
Motor
Shea
ve
P
osition
External
Static
Pressures
(Inc
hes
W
ater
Column)
1.1
1.2
1.3
1.40
1.50
1.60
1.7
1.80
1.90
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
c
FM
RPM
Kw
Fully Closed
6000
1353
4.45
5650
1354
4.25
5350
1355
4.00
4850
1357
3.75
4400
1359
3.50
1/2 T
ur
n
Open
5700
1333
4.13
5325
1334
3.93
4925
1336
3.70
4475
1338
3.48
1 T
ur
n
Open
6100
1309
4.25
5800
1310
4.00
5400
1312
3.80
5000
1314
3.60
4500
1316
3.40
1.5 T
ur
ns
Open
5850
1290
4.03
5550
1291
3.78
5150
1293
3.55
4725
1295
3.35
2.0 T
ur
ns
Open
6200
1270
4.10
5600
1271
3.80
5300
1272
3.55
4900
1273
3.30
4450
1275
3.10
2.5 T
ur
ns
Open
5850
1250
3.80
5350
1251
3.55
5050
1252
3.33
4650
1253
3.09
3.0 T
ur
ns
Open
5800
1228
3.65
5500
1230
3.50
5100
1231
3.30
4800
1232
3.10
4400
1233
2.87
3.5 T
ur
ns
Open
5575
1208
3.43
5250
1210
3.25
4850
1211
3.03
4500
1212
1.55
4.0 T
ur
ns
Open*
5350
1188
3.2
5000
1189
3.00
4600
1190
2.75
4.5 T
ur
ns
Open
5100
1168
2.98
4700
1169
2.75
5.0 T
ur
ns
Open
4850
1148
2.75
4400
1148
2.50
ta
B
l
E
l
EGEND:
* Denotes F
actor
y shea
ve setting.
Shaded areas not recommended f
or unit oper
ation.
Boldf
ace type indicates f
actor
y recommended b
lo
w
er oper
ating r
ange
.
See Accessor
y P
erf
or
mance Data tab
le f
or additional static pressure inf
or
mation.
V
alues include losses f
or air filters unit casing and dr
y e
vapor
ator coil.
Table 5. R6GN-180C Series