beautypg.com

1 boom roll sensor mounting, 2 chassis roll sensor mounting – NORAC UC4+BC+AN2 User Manual

Page 25

background image

22

4.6.2.1 Boom Roll Sensor Mounting
The boom roll sensor (E04) must be
mounted to the rotating part of the boom.

Follow these guidelines and refer to Figure
22
and Figure 24 to mount the sensor.

a) Make sure you are using the roll sensor

that does NOT have a temperature
probe (only one cable) (E04).

b) The boom roll sensor must be mounted

to the rotating part of the boom
suspension.

c) Use cable-ties to secure the bracket to

a square edge feature (square tube).

d) Ensure the AMP (circular) connector

exits towards the Right Hand Wing
(when looking from the rear of the
sprayer).

e) Securely cable-tie the connector to the

frame.

4.6.2.2 Chassis Roll Sensor Mounting
The chassis roll sensor must be mounted to
a non-rotating part of the boom.

a) Make sure you are mounting the roll

sensor that does have a temperature
probe (2 cables) (E03).

b) Mount the chassis roll sensor (E03) to a

non-rotating part of the boom.

c) Cable-tie the bracket to a square edge

feature (square tube).

d) The AMP (circular) connector MUST

exit towards the Right Hand Wing
(when looking from the rear).

e) Securely cable-tie the connector to the

frame.

Figure 23: Boom and Chassis Roll Sensors Correctly Mounted

E04

E03