4.6.1.2 Chassis Roll Sensor Mounting
1. It is often best to cable tie the chassis

roll sensor in place. When mounting

the chassis roll sensor follow the
guidelines and refer to Figure 21.

The chassis roll sensor must be

mounted on a portion of the
sprayer that does not pivot and is
as close to the boom frame roll
sensor as possible (Figure 19).

a) Make sure you are using the roll sensor

with the temperature probe (E03).

b) Ensure the roll sensor is level with

respect to the chassis.

c) The AMP (circular) connector MUST

exit towards the right hand wing.

d) Make sure the temperature probe is

able to reach the side of the valve block.

Figure 21: Chassis Roll Sensor

Mounting

2. Refer to Section 4.6.4 for mounting

the temperature probe.