beautypg.com

5 main lift sensor installation – NORAC UC4+BC+AN2 User Manual

Page 19

background image

16

4.5 M

AIN

L

IFT

S

ENSOR

I

NSTALLATION

1. Assemble the main lift sensor bracket

(B11) as shown in Figure 14.

Figure 14: Main Lift Sensor Bracket

2. The bracket can then be mounted to

the lowest frame member on the center
section of the sprayer. The bracket
should be mounted so the sensor
mounting collar is in approximately the
center of the sprayer and ahead of the
boom (Figure 15 and Figure 16).

The sensor mounting collar must

not be behind the sprayer’s
wheel.

The General Mounting Rules for

UC4+ Ultrasonic Sensors, from
the previous section, must be
followed.

Figure 15: Main Lift Sensor Bracket

Mounting Position

3. Mount the sensor onto the sensor

mounting collar (Figure 15).

Figure 16: Main Lift Sensor Mounted

in the Correct Location

Bracket Tube

Sensor

Mounting Tab

Sensor Mounting

Collar

Bracket Base