Callcleared codes from 3.6.4/v.58-1994, Conexant – Longshine LCS-8056C2 User Manual
Page 79
![background image](/manuals/698242/79/background.png)
Commands for Host-Processed Modems Reference Manual
100498E
Conexant
3-57
callCleared codes from 3.6.4/V.58-1994
callCleared: indicates that the DCE has gone on hook and that the previously existing network
connection has been cleared. These value are hex, converted from decimal in V.58.
callCleared codes are described in Table 3-11.
Table 3-4. AT#UD Last Call Status Report Format
Key
Value(s)
Definition
0
2 digits
Diagnostic Command Specification revision number, digit.digit
1
Table 3-4
Call Setup Result code
2
Table 3-5
Multi-media mode
3
Table 3-7
DTE-DCE interface mode
4
String
V.8 CM octet string, same format as V.250, in quotes
5
String
V.8 JM octet string, same format as V.250, in quotes
10
0-2F
Received signal power level, in –dBm (0-43)
11
0-1F
Transmit signal power level, in –dBm (e.g., 0-17)
12
0-64
Estimated noise level, in –dBm (e.g., 10-90)
17
0-FFF
Round Trip delay, in units of ms
18
Table 3-7
V.34 INFO bit map
20
Table 3-8
Transmit Carrier Negotiation Result
21
Table 3-8
Receive Carrier Negotiation Result
22
0-1F40
Transmit Carrier symbol rate (0-8000) in symbol/s
23
0-1F40
Receive Carrier symbol rate (0-8000) in symbol/s
24
0-FA0
Transmit Carrier frequency (0-4000) in Hz
25
0-FA0
Receive Carrier frequency (0-4000) in Hz
26
0-FA00
Initial transmit carrier data rate (0-64000) in bit/s
27
0-FA00
Initial receive carrier data rate (0-64000) in bit/s
30
0-FF
Temporary carrier loss event count
31
0-FF
Carrier Rate re-negotiation event count
32 0-FF
Carrier
Retrains
requested
33
0-FF
Carrier Retrain requests granted
34
0-FA00
Final transmit carrier data rate in bit/s
35
0-FA00
Final receive carrier data rate in bit/s
40
Table 3-9
Protocol Negotiation Result
41
0-400
Error Control frame size in bytes
42
0-FF
Error control link timeouts in transmission
43
0-FF
Error control link NAKs received
44
Table 3-10
Compression Negotiation Result
50
0-2
Transmit flow control: 0 = off; 1 = DC1/DC3; 2 = V.24 circuit
106/133
51
0-2
Receive flow control: 0 = off; 1 = DC1/DC3; 2 = V.24 circuit
106/133
52 0-FFFFFFFF
Transmit
characters sent from DTE
53
0-FFFFFFFF
Received characters sent to DTE
54
0-FFFF
Transmit characters lost (data overrun errors from DTE)
55
0-FFFF
Received characters lost (data overrun errors to DTE)
56
0-FFFFFFFF
Transmit I- Frame count, if error control protocol running
57
0-FFFFFFFF
Received I-Frame count, if error control protocol running
58
0-FFFF
Transmit I-Frame error count, if error control protocol running
59
0-FFFF
Received I- Frame error count, if error control protocol running
60
Table 3-11
Termination Cause
61
0-FF
Call Waiting event count