Syntax, Result code, W - store current configuration – Longshine LCS-8056C2 User Manual
Page 53
Commands for Host-Processed Modems Reference Manual
100498E
Conexant
3-31
&V - Display Current Configuration and Stored Profile
This command reports the current (active) configuration and the stored (user) profiles.
Syntax
&V
Result Code
OK
Example:
AT&V
ACTIVE PROFILE:
E1 L1 M1 Q0 T V1 X0 &C1 &D2 &G0 &T0
S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:004
S07:050 S08:004
S10:014 S12:050 S16:000 S18:000 S29:070
STORED PROFILE 0:
E1 L1 M1 Q0 T V1 X4 &C1 &D2 &G0 &T0
S00:000 S02:043 S06:004 S07:050 S08:004 S10:014 S12:050
S18:000 S29:070
OK
&W - Store Current Configuration
This command saves the current (active) configuration (profile), including S-Parameters, in
the Registry. The current configuration is comprised of a list of storable parameters illustrated
in the &V command. These settings are restored to the active configuration upon receiving an
Z command or at power up.
Syntax
&W
Result Code
OK