beautypg.com

Reporting current or selected values, Reporting supported range of parameter values – Longshine LCS-8056C2 User Manual

Page 75

background image

Commands for Host-Processed Modems Reference Manual

100498E

Conexant

3-53

Decimal number which specifies if Non Return to Zero Inverted
(NRZI) encoding is to be used by the modem for transmit and
receive data. The options are:

0

NZRI encoding and decoding disabled (default and
fixed).

,

Decimal number which specifies the octet value(s) to be used
while performing character-oriented framing. is to be
commanded to 255 (FFh); is not to be commanded.

Reporting Current or Selected Values

Command: +ESA?

Response: +ESA:

,,>,,,,,

Example:

+ESA: 0,0,0,,0,0,255,

For the defaults.

Reporting Supported Range of Parameter Values

Command: +ESA=?

Response: +ESA: ( range), ( range),( range),

( range),
( range), (
range),( range), ( range)

Example: +ESA:

(0),(0),(0-1),

,(0),(0),(255)