KERN & SOHN KXS-TM User Manual
Page 107
19.5.4 Amend the DATA Hold function of verified weighing system
(function „CFn 05“)
Call up function „CFn 05“, see chapter 18.
Press the TARE-key, current setting appears.
Select desired settings with TARE or UNIT key.
hold 0
Function switched off (factory setting)
hold 1
Peak value function
This function indicates the highest load factor (peak value) of a
continuously rising load. The peak value remains in the display until it
is deleted with any key.
hold 2
„Stable hold 1“ mode
The weight value is held automatically after reaching a stable value
up to the manipulation of any key in the display.
hold 3
„Stable hold 2“ mode
The weight value is held in the display after reaching a stable value
until the load falls under 10d.
hold 4
Animal weighing (see chap. 10.6.1)
This function is suitable for jerky weighing procedures, see following
chapter 10.6.1
KXS/KXG-TM-BA_IA-e-1420