28

TruVision NVR 20 User Manual

Note:

By default every camera added to the system is automatically enabled for

7x24 continuous recording.

The TVN 20 uses a maximum of two recording profiles (independent frame rate,
resolution, and bandwidth) with recording schedules. Not all listed IP cameras
support two recording profiles. Where the camera supports, the two possible
profiles are (check the IP Compatibility Chart for specifics):

• Main (Normal) - associated with Scheduled/Time-Lapse Recording

• Main (Event) – associated with Motion and Alarm Recording

• SubStream – available only for live view in multi-camera display through

the browser and Interlogix TruVision Navigator software (if supported by
the camera)

Table 3: IP Compatibility Chart

Record Mode

Description

Multiple Profile IP
Cameras (used
Profile)

Single Profile IP
Cameras

Live Stream*

Schedule Record

Time-Lapse or Continuous
Recording

Main - Normal

Main - Normal

Main – Normal
(Substream if
available)

Motion Detection

Event recording triggered
by IP Camera motion
detection

Main - Event

Main - Normal

Main - Event

Alarm Recording

Event recording triggered
by any of the TVN 20’s on-
board analog alarm inputs.

With some cameras, the
digital alarm inputs from
the IP Camera may be
used

Main - Event

Main - Normal

Main - Event

Motion Detection /
Alarm

Recording is triggered
either if there is a motion
detection OR an alarm
input is triggered (OR-
Gating)

Main - Event

Main - Normal

Main - Event

Motion Detection &
Alarm

Recording is triggered only
if there is motion detection
AND an alarm input (And-
Gating)

Main - Event

Main - Normal

Main - Event

* If the IP Camera supports only a single encoding parameter in the TVN 20, only that stream is available for