beautypg.com

Carrier V2203-DI (26--00128) User Manual

Page 61

background image

3--2

62--11362

3.2

SERVICING

3.2.1 Rotor Lobe Clearance

1. Measure the clearance between lobes of the inner ro-

tor and the outer rotor with a feeler gauge.

2. Measure the clearance between the outer rotor and

the pump body with a feeler gauge.

3. If the clearance exceeds the factory specifications,

replace the oil pump rotor assembly.

Inner/Outer

Rotor Clearance

Factory

Specification

0.03 to 0.14 mm

0.0012 to 0.0055 in.

Allowable

Limit

0.2 mm

0.008 in.

Outer Rotor/

Pump Body

Clearance

Factory

Specification

0.11 to 0.19 mm

0.0044 to 0.0074 in.

Allowable

Limit

0.25 mm

0.0098 in.

3.2.2 Rotor to Cover Clearance

1. Put a strip of plastigage onto the rotor face with

grease.

2. Install the cover and tighten the bolts.

3. Remove the cover carefully, and read the plastigage.

4. If the clearance exceeds the factory specifications,

replace the oil pump rotor assembly.

Rotor/Cover

Clearance

Factory

Specification

0.105 to 0.150 mm

0.00414 to 0.00590 in.

Allowable

Limit

0.20 mm

0.008 in.