] interface block, ] serial interface 1, ] serial interface 2 [02-] serial interface 3 – Flintec FT-15D User Manual
Page 36: 7 setup, 000 4] data format, 001 3] baud rate, 002 0] handshake, 004 0] data length and parity, 005 0] checksum, 010 0] data format

FT-15(D) Technical Manual, Rev. 1.02 August 2010
Page 36 of 52
Transit weighing
11.2.7 Setup
[0--] Interface Block
You can access the parameters of the instruments’s serial interface(s) in parameter section [0--].
The data output modes can be used only once per instrument except for continuous data output.
[00-] Serial Interface 1
The parameters of the 1
st
serial interface (= standard serial interface).
[000 4] Data Format
0 : No data transfer
1 : Continuous data output
2 : PC-Software interface mode (with ASCII P and Z) 3 : Host mode
4 : Ticket and report printer (default)
[001 3] Baud Rate
0 : 1 200 Baud
1 : 2 400 Baud
2 : 4 800 Baud
3 : 9 600 Baud (default)
4 : 19 200 Baud
5 : 38 400 Baud
6 : 57 600 Baud
[002 0] Handshake
0 : No Handshake (default)
1 : Xon/Xoff
[003 00] Address
The address range is 1 to 99. If you enter 0, the indicator will operate without an address.
[004 0] Data Length and Parity
0 : 8 bit, no parity (default)
1 : 7 bit, odd parity
2 : 7 bit, even parity
[005 0] Checksum
0 : Checksum byte disabled (default)
1 : Checksum byte enabled
[01-] Serial Interface 2
[02-] Serial Interface 3
This sub-block includes the parameters of the 2
nd
serial interface respective 3
rd
serial interface.
[010 0] Data Format
respective
[020 0] Data Format
0 : No data transfer
1 : Continuous data output (default)
2 : PC-Software interface mode (with ASCII P and Z) 3 : Host mode
4 : Ticket and report printer (default)
[011 3] Baud Rate
respective
[021 X] Baud Rate
0 : 1 200 Baud
1 : 2 400 Baud
2 : 4 800 Baud
3 : 9 600 Baud (default)
4 : 19 200 Baud
5 : 38 400 Baud
6 : 57 600 Baud
[012 0] Handshake
respective
[022 0] Handshake
0 : No Handshake (default)
1 : Xon/Xoff
2 : Hardware (for serial interface 2 only)
Warning:
If you choose Hardware as handshake, then the serial interface 3 can not be used as RS232C.
[013 00] Address
respective
[023 00] Address
The address range is 1 to 99. If you enter 0, the indicator will operate without an address.
FLINTEC GmbH
Tel : +49 6226 9240 0
Fax : +49 6226 9240 99
Meckesheim, Germany