FT-15(D) Technical Manual, Rev. 1.02 August 2010
Page 17 of 52
Second weighing cycle without printing first weighing label (parameter 045=0):
Steps
Vehicle
Position
Description
There is no vehicle
on the weighbridge.
(Unloaded Scale)
If the indication is not 0 kg, press the
instrument ready status.
[
0
kg ]
Vehicle is parked on
the scale and the
engine is stopped.
Load the scale.
[
28680 kg
]
Press the
weighing cycle.
[ Second ]
Message will be displayed for 1 second.
[ V. Id ]
[
584
]
Enter the vehicle ID numerically to select
the first weighing data from the temporary
memory.
Press the
[ First
]
[
9760 kg
]
The first weight in the memory will be
displayed. Press the
the next step
[ Id1 ]
[
78
]
Press the
memory or press the
numeric entry, if this entry is defined for the
second weighing (refer to parameter [043]).
Press the
[ Id2 ]
[
22
]
Press the
memory or press the
numeric entry, if this entry is defined for the
second weighing (refer to parameter [044]).
Press the
]
[
28680 kg
]
If the vehicle has finalized the weighing
process, press the
print the weighing result.
[ Unload
]
[
28680 kg
]
Message appears until the scale gets
unloaded.
Vehicle is on the
scale + the displayed
weight is stable.
Vehicle leaves the
scale.
Unload the scale.
[
0 kg
]
If the displayed weight is less than 20e or
the
the instrument ready status.