First weighing cycle without printing first weighing label (parameter 045=0):
Steps
Vehicle
Position
Description
There is no vehicle
on the weighbridge.
(Unloaded Scale)
If the indication is not 0 kg, press the
instrument ready status.
[
0
kg ]
Vehicle is parked on
the scale and the
engine is stopped.
Load the scale.
[
9760
kg ]
Press the
weighing cycle.
[ First ]
Message will be displayed for 1 second.
[ V. Id ]
[
584
]
Enter a vehicle ID number numerically (up
to 6 digits) as a first weighing code.
Press the
[ Id1 ]
[
78
]
Press the
memory or press the
numeric entry, if this entry is defined for the
first weighing (refer to parameter [043]).
Press the
[ Id2 ]
[
22
]
Press the
memory or press the
numeric entry, if this entry is defined for first
weighing. (refer to parameter [044]).
Press the
[Save W ]
[
9760
kg ]
If the vehicle has finalized the weighing
process, press the
weighing result.
[ Unload ]
[
9760
kg ]
Vehicle is on the
scale + the displayed
weight is stable.
Message appears until the scale gets
unloaded.
[
0
kg]
Vehicle leaves the
scale.
Unload the scale.
If the displayed weight is less than 20e or
the
the instrument ready status.
Press the
If the vehicle ID already exist in the first memory the [Change ] message will be displayed.
Go to the temporary first weighing memory to delete the first weighing record.
[Code FL]
message appears, if the temporary first weighing memory is full. Check the memory for records
which can be deleted or wait until any second weighing cycle to free memory for a new 1
st
weighing.