10 a, ] metrological data block, ] legal metrological records – Flintec FT-15D User Manual
Page 30: Libi, Emory and, Egal, Etrological, Ecords

FT-15(D) Technical Manual, Rev. 1.02 August 2010
Page 30 of 52
10 A
LIBI
M
EMORY AND
L
EGAL
M
ETROLOGICAL
R
ECORDS
FT-15(D) keeps the last 9 583 weighing records in the loop alibi memory. The ticket number, which is also the
alibi record number, cannot be changed manually. This data records can be shown on the indicator’s display or
can be transmitted via serial port.
The reports initiated by the report keys located on the instrument’s front can also be used as an alibi memory
report, if they include the required records.
Empty records will be printed as ------ , the characters “PT” are located on the right of a preset vehicle weight
value, the message “Transit“ will be printed in the first weighing column of a transit weighing record and
corrupted records will be printed as ******. For the records, where a weighing result is not available, the
message [ no rec ] will be shown on the display.
After installing the alibi board or changing the main board “Error 41” or “Error 42” will be shown on the display
after power on because the activation of the alibi memory is required.
If the calibration jumper is short circuited, you can activate the alibi board by pressing the
power on. Otherwise the alibi errors will disappear by pressing the
(Error “40” will be shown after pressing the
Alibi report form:
ALIBI MEMORY RECORD FILE
09.01.2009 17:10
Ticket
Date Time Vehicle
Customer
Commodity
1.Weight kg 2.Weight kg Net kg
---------- ------------- --------- --------------- ------------------ ------------------ --------------- ----------------- ----------
000234
01.01.09 08:12
1111
Customer A
Sample A
33320 11100
22220In
000235
03.01.09 09:42
2222
No entry
No entry
Transit 44440
-------Tr
000236
08.01.09 12:10
3333
23456
123456
11100 PT 55560
44460PV
000237
12.01.09 17:22
4444
Customer B
Sample B
12220 22220 10000Out
000238
13.01.09 09:13
0
0 33330 33330PC
To find a definite record you have to enter parameter [802]. After reaching the desired record, the recorded data
can be viewed in the display. If needed you can print this record together with the following 9 records by
pressing the
port. The
[8--] Metrological Data Block
The parameters about Metrological Registry are being entered in this section.
[80-] Legal Metrological Records
In this block edit the parameters with <
> key and use the
description.
[800] Counter
This counter increases automatically by 1 after starting the setup mode with enabled calibration jumper and service
password. This counter cannot be changed manually.
[801] Alibi
Memory)
0 = Disabled
1 = Enabled
[803]
Print all Alibi Memory records
All data from the Alibi Memory can be printed by pressing the
[804] Alibi
Info
You can get some basic information about the alibi memory board and the records by pressing the
These data are:
SN :
Pin code of the alibi memory card
SA :
The alibi record start number within this indicator
LA :
The alibi record number of the next weighing with this indicator
CN :
Calibration counter number
CS :
Check sum status
AS :
Capacity of the alibi memory
LD :