Ingressus can support 2 types of door lock output, either wet contact
or dry contact. For wet contact, Ingressus can output power to the door
lock system. You can supply additional power supply this is suitable with
the door lock system to Ingressus the maximum is 12VDC 3A. For dry
contact, Ingressus outputs relay signal to door lock system. You must
install an independent power supply to the door lock system. Ingres-
sus will only output relay signal to the door lock system to unlock/lock
it. Dry contact is a more secure installation because door lock systems
have their own power supply, it remains working even though Ingressus
is powered down.
Ingressus II and IV can support AUX input and output. You can install
sensors/detectors for example smoke detector as AUX input and alarm
as AUX output. When the smoke sensor triggers, Ingressus will trigger
the alarm to alert all users. You can configure in Ingress software to un-
lock all doors in case of fire or smoke detected. See the technical specifi-
cations to learn the kinds of AUX input/output available.
The Ingressus comes with its management software, Ingress. Ingress
stores a copy of user information and entry-exit records in PC/server.
An administrator can always update user information and restriction of
access to every Ingressus. An administrator can preview and print useful
reports to check entry-exit of each user. Ingress also works as a monitor-
ing station for all connected Ingressus to enhance security levels of the
environment.
Ingressus provides 2 types of communications to Ingress. You can link
up multiple units of Ingressus by using RS485 network or using TCP/IP
(LAN) to a single Ingress. With Ingress, you can now have all entry-exit
control of all users on a server for easy management.