1.7. Restoring the default parameters
• Press the [ENCODER] button for 4 seconds, the PA label appears on the display.
• Press the [ENCODER] button to display the corresponding value
• Turn the encoder within 15 seconds to set the value at 743.
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
• Press the [ENCODER] button for 4 seconds, the dEF label appears on the display
• Press the [ENCODER] button to display the corresponding value
• Turn the encoder within 15 seconds to set the 149 value.
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds. The
display will show the flashing dEF message for 4 seconds.
To exit the procedure
• Press the [ENCODER] button for 4 seconds.
1.8. Modification of the magnitude shown on the display
The display can show the value of probe 1, the set-point value or the timer value (setting
or count in progress).
To modify the magnitude shown on the display
• Press the [B3] key for 1 second. LED L3 is on if the data shown on the display is the
work set-point. The min LED is on if the data shown on the display is the setting of the
timer and the timer is in the stop status.
1.9. Silencing the buzzer
Press a key or the [ENCODER] button. The buzzer rings for
• probe
1
error
• probe
2
error
• temperature
alarm
• board temperature alarm
• the first time the temperature reaches the set-point
• at the end of timer count
• depending on the status of the digital inputs, further details are seen in the following
paragraphs
1.10.
Displaying probe 2 temperature
To access the procedure
• Make sure the probe is enabled.
• Press the [B3] key, the Pb2 label will appear on the display.
To display the board temperature value
• Press the [ENCODER] button.
To exit the procedure
• Do not operate on the keyboard for 15 seconds
or
• Press the [ENCODER] button to go back to display of the Pb2 label.
• Press the [B3] key or do not operate on the keyboard for 15 seconds