Page 3: Setting the configuration parameters
![background image](/manuals/675421/3/background.png)
3/13
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
1.3. Timer start
• Press the [B4] key for at least 1 second, the min LED flashes.
Alternatively
• Press the [B5] key for at least 1 second, the min LED flashes.
1.4. Timer stop
• Press the [B4] key for at least 1 second.
Alternatively
• Press the [B5] key for at least 1 second.
1.5. Modifying the count
The count value can be set within 0 and 99 minutes. Setting the count value at 0 means
putting the timer in the stop status.
To access the procedure
• Make sure the timer is in the start status.
• Press the [B4] key, the min LED flashes, the value on the display flashes.
Alternatively
• Press the [B5] key, the min LED flashes, the value on the display flashes.
To modify the value
• Turn the encoder within 15 seconds
To exit the procedure
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
1.6. Setting the configuration parameters
To access the procedure
• Make sure that the instrument is in the STOP status.
• Press the [ENCODER] button for 4 seconds, the PA label appears on the display.
• Press the [ENCODER] button to display the corresponding value
• Turn the encoder within 15 seconds to set the value at -19.
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
• Press the [ENCODER] button for 4 seconds, the first parameter label appears on the
display.
To modify a parameter:
• Turn the encoder within 60 seconds to select a parameter.
• Press the [ENCODER] button to display the corresponding value
• Turn the encoder within 15 seconds to set the desired value.
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
To exit the procedure
• Press the [ENCODER] button for 4 seconds or do not operate on the keyboard for 60