beautypg.com

EVCO EVC30S40J7XXX09 User Manual

Page 12

background image

12/13

output can be activated at the start of the cycle following deactivation
of the input.

4.11. Some regulation times

4.11.1. Example 1


Initial conditions

P5=0
Preservation not selected from key

Operation

P.I.D. regulation on P2 (dedicated parameters P11…P15)

LED

L1 on if probe 1 in [P2-P6,P2+P6]

L1 flashing if probe 1 is outside [P2-P6,P2+P6] range for time P7

L2

off

What can I do?

Press the [MELT] key for 1 second and pass to pre-heat mode if probe 1

Press the [MELT] key for 1 second and pass to preservation mode if probe 1

≥P8

4.11.2. Example 2


Initial conditions

P5=1
Preservation not selected from key

Operation

Pre-heat mode until probe 1 reaches P8 for the first time
P.I.D. regulation on P2 (dedicated parameters P11…P15) once pre-heating has
ended

LED

L1 flashing during pre-heat

L1 on if pre-heat ended and probe 1 in [P2-P6,P2+P6]
L1 flashing pre-heat terminated and if probe 1 is outside [P2-P6,P2+P6] range for
time P7

L2

off

What can I do?

Press the [MELT] key for 1 second to pass to preservation mode

4.11.3. Example 3


Initial conditions

Preservation selected by pressing the key [MELT] before Start.

Operation

Pre-heat mode until probe 1 reaches P8 for the first time
Preservation i.e. P.I.D. regulation on P8 (dedicated parameters P11…P15) once
pre-heating has ended

LED