Parameters

Buzz On Key

0

2

- - -

2

Modality to use to utter the beep while pressing

an area of the user interface

0

= the beep is never uttered

1

= the beep is always uttered

2

= the beep is uttered only if the area

is sensitive

Parameters

Print Frame

0

1

- - -

0

Showing frames instead small size pages

1 =

yes

CAN Network

MyNode

1

127

- - -

99

Local (or of the interface) CAN node’s address

CAN Network

Master

- - -

- - -

- - -

YES

The interface always works as master

CAN Network

Baud

- - -

- - -

- - -

Auto

CAN communication baud rate

20K =

20,000

baud

50K =

50,000

baud

125K =

125,000

baud

500K =

500.000

baud

Auto

= the interface recognizes the baud

rate automatically, on condition

that it is one of the those

mentioned above

One suggests modifying the value of the

parameter and assign each device in the network

the same baud rate.

CAN Network

Net Timeout

1

240

s

5

Remote (or of the devices in the network) CAN

communication time-out (after this time without

CAN communication with a device, this will be

excluded by the network)

CAN Network

Network Node

[1] 1

[32] 127

- - -

- - -

Remote (or of the devices in the network) CAN

nodes’ address; example for [1] 2:

[1] =

node

2 =

node’s

address

Modbus

Address

1

247

- - -

1

Modbus address (reserved)

Modbus

Parity

- - -

- - -

- - -

even

Modbus communication parity (reserved)

none =

no

parity

odd =

odd

even =

even