1 3. troubleshooting chart – Toshiba IK-M41R2 User Manual
Page 27
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

1 3. TROUBLESHOOTING CHART
Symptoms
Possible causes
No image
• Is power properly supplied?
• Is the lens iris adjusted properly?
• Is the TV monitor adjusted properly?
• Is the switch for mode setting set properly?
• Is RR VD input at reset/restart mode?
• Is trigger input at one-pulse trigger mode?
Dark image
• Is shutter speed set properly?
External sync,
is not
available.
• Is the switch for mode setting set properly?
• Is external input pulse input at correct phase?
• Is external input pulse input within the specified frequency
range?
• Is 75Q ON/OFF switch positioned properly? (Is 75Q terminal is
necessary for the signal input from the external unit or TTL
level?)
• Is external Input pulse input from HDA/D terminal, and DC IN/
SYNC terminal simultaneously? (The pulse should be input from
one terminal only.)
14. CONFIGURATION
(1| IIC-M41P2, IK.M41R2
(1) Camera head (attached to head cover)
(2) Camera control unit
(3) Accessories
(a) Camera holder
(b) 4-pin connector (HR 10A-7-P-4S)
(c) Instruction manual
Camera control unit
27